Distal Radius

Home > Products > Hand & Wrist > Distal Radius

Distal Radius

  • Total Wrist Fusion Plating System

    Acumed Total Wrist Fusion Plating System

    The Total Wrist Fusion Plating System was designed for wrist arthrodesis due to deformities associated with degenerative arthritis, brachial plexus palsies, and spastic disorders. This five plate system features both innovative and traditional designs.

    Specifically, four of the five plates are positioned on the second metacarpal. These left and right specific designs are positioned on the second metacarpal which may reduce extensor tendon irritation. Additionally, the fifth plate is a neutral option that is placed on the third metacarpal and developed for use with a proximal row carpectomy.

  • Acu-Loc Wrist Spanning Plate

    The Acu-Loc Wrist Spanning Plate is designed to address complex distal radius fractures. This temporary fixator is designed to hold the wrist in distraction and to provide ligamentotaxis to the wrist on a temporary basis while the distal radius heals. Similar to an external fixation device, the Acu-Loc Wrist Spanning Plate may be used if the distal radius is too comminuted for an Acu-Loc 2 or other distal radius plate. The advantage of this plate is its simplicity using the concept of ligamentotaxis to apply circumferential pressure created by distracting the affected area to push fragments back in place.

  • Acu-Loc Extra-Articular (EX) Plates

    Acu-Loc Extra-Articular EX Plates

    The Acumed Acu-Loc Extra-Articular Plate is designed for extra-articular distal radius fractures and osteotomies. The plate sits more proximally than the standard Acu-Loc Volar Distal Radius Plate, and its distal locking screws are angled to support the dorsal lip of the radius, maximizing purchase in the subchondral bone. The 2.3 mm Variable Locking Screws can also be used in the distal holes of this plate family.

  • Acu-Loc Dorsal Distal Radius Plate

    Acumed Acu-Loc Dorsal Plate

    Acumed Acu-Loc Dorsal Plates are designed for complex distal radius fractures that need to be addressed from the dorsal side. The plates are anatomically contoured and may help restore the bone's natural anatomy from the distal ulnar side to the radial styloid. In addition, the distal cage of screws - with fixed angle locking technology - are designed to help support the fracture.

  • Acu-Loc Volar Distal Radius (VDR) Plate

    Acu-Loc Volar Distal Radius VDR Plate

    The Acumed Acu-Loc Volar Distal Radius (VDR) Plate has been a market leader since 2004. Designed to provide a more distal fit than many other volar plates, the Acu-Loc Volar Distal Radius (VDR) Plate offers an innovative solution for complex intra-articular distal radius fractures and osteotomies. The Acu-Loc instrumentation supplies surgeons with everything necessary to implant all of the distal radius and volar distal ulna plates. The system features clamps, retractors, and soft tissue protectors, as well as drivers, drills, and targeting assemblies.

  • Distal Radius Fragment Specific Plates

    Acumed Distal Radius Fragment Specific (DRFS) Plates are designed to independently address the fractures of the intermediate and radial columns. The modular nature of the plates, which include the Dorsal Rim Buttress Plate, Dorsal Lunate Plate, Volar Lunate Suture Plate, and Divergent Radial Styloid Plate, allows compression of fracture fragments from multiple directions.

  • Arc Wrist Tower

    The Acumed Arc Wrist Tower is designed to provide stable traction of the patient's forearm and hand, allowing unrestricted access to the wrist during arthroscopic and fracture-reduction procedures. The support arm swivels 180-degrees about the patient's elbow and forearm, allowing for fluoroscopic imaging from any angle. 

  • Acu-Loc 2 Proximal Volar Distal Radius (VDR) Plates

    Acu-Loc 2 Proximal Volar Distal Radius VDR Plates

    The Acumed Acu-Loc 2 Proximal Volar Distal Radius (VDR) Plates are designed for distal radius fracture and osteotomies, as well as segmented diaphyseal fractures. Customizable plate length and width options allow for sizing of varying patient anatomies.

    In addition, converging ulnar screws, suture holes, and K-wire holes have been incorporated to support the volar ulnar lip and lunate facet. The 2.3 mm Variable Angle screws can also be used with this plate family.

  • Acu-Loc 2 Standard Volar Distal Radius (VDR) Plate

    Acumed Acu-Loc 2 Standard Volar Distal Radius Plate

    Acumed Acu-Loc 2 Standard Volar Distal Radius Plates have an optimized design to closely replicate the anatomical contours of the distal radius and assist in restoring its natural geometry.

    Other optimized features include a lower profile, polished finish which may help minimize soft tissue irritation, and converging ulnar screws, additional suture holes, and added K-wire holes for provisional fixation.

  • Acu-Loc 2 Extension Plates

    Acu-Loc 2 Extension Plate

    Acumed Acu-Loc 2 Extension Plates are designed to lock to Acu-Loc 2 Proximal VDR Plates to provide rigid fixation of segmental fractures of the distal radius that extend into the diaphyseal region. The proximal plate end is tapered and the undersurface is designed for limited contact with the bone.

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.