OsteoMed ICON Facial Plating System

For treatment of Cranial Reconstruction
Overview

The ICON™ Facial Plating System is OsteoMed's next-generation CMF surgical solution. Each of the 1.2, 1.6, 2.0, and 2.4 mm modules are completely customizable with individual plate and screw tags.

System design features, such as the built-in auxiliary mesh tray and utility tray, offer space to include larger meshes, orbital floor plates, and optional instrumentation.

This system can either be a three-module or two-module configuration.

Indications for Use

Maxillofacial Indications Only:

  • The ICON Modular Locking Fixation System is comprised of plates, screws and instrumentation for fracture fixation in maxillofacial trauma reconstruction, mandibular reconstruction and orthognathic reconstruction.
  • The MMF / IMF Screws are indicated for temporary ligature and wire lock fixation for temporary constriction and stabilization of fractured bone segments in the oral cavity in conjunction with primary fixation devices.
  • The 2.0 Locking Plate System is indicated for oral, maxillofacial surgery; trauma; reconstructive surgery; and orthognathic surgery (surgical correction of dentofacial deformities). Screws and Plates are intended for single patient use only.
  • The  ICON Modular Locking Fixation System (2.8mm thickness plates) is indicated for fracture fixation in maxillofacial trauma reconstruction, mandibular reconstruction and orthognathic reconstruction. Note: The ICON 2.8mm thickness plates are not to be placed on craniofacial fractures (PN: 231-2801, 231-2802, 231-2811, 231-2812, 231-2813, 2312814, 231-2821, 231-2822)
  • The Low Profile Orbital Floor Plate System is intended to be used in the reconstruction of the floor and/or medial wall of the orbit. The OsteoMed Low Profile Plate System is indicated for the reconstructive treatment of orbital floor and/or medical wall trauma or bone excision in adult patients.

Cranial Maxillofacial Indications Only:

  • The CFxTM Rigid Fixation Systems are indicated for fracture fixation during cranial and facial trauma reconstructions, orthognathic reconstruction, mandibular reconstruction and surgery involving osteotomies and trauma.
  • The Angulated Locking Fixation System is indicated for mandibular fracture fixation in cranio-maxillofacial trauma reconstruction, mandibular reconstruction and orthognathic reconstruction.

Also related to Cranial Reconstruction procedure:

Abyrx Montage
An FDA-cleared, settable (hardening) bioabsorbable polymer and hydroxyapatite/ beta tricalcium phosphate-based putty, for use in the control of bleeding from bone during spine, orthopedic, trauma, cra...
Image
Matrix Omnipore Customized Surgical Implants
OsteoMed partners with Matrix to distribute OMNIPORE Customized Surgical Implants. These implants are manufactured from a linear form of high-density polyethylene (HDPE). Polyethylene has a long histo...
Image
OsteoMed OsteoMatch Patient Matched Implants
OsteoMatch PEEK Patient-Specific Cranial Implants are individually sized and shaped implantable prosthetic cranioplasty implants intended to correct defects/replace voids in the cranial skeleton of a ...
Image
OsteoMed Pinnacle Smart Power Driver
The Pinnacle Battery Powered Smart Driver features an ergonomic pencil grip. OsteoMed's torque-limiting software is based on exhaustive screw characterization. It senses when any OsteoMed screw is ful...
Image
OsteoMed SmartFlex Pediatric Cranial Expander
SmartFlex is a pediatric cranial expander featuring pre-formed cranial springs. The SmartFlex is manufacture with medical grade stainless steel with beveled foot plates designed to fit securely under ...
Image

In addition to treating Cranial Reconstruction, the OsteoMed ICON Facial Plating System can also be used in the following procedures:

Orthognathic Surgery (Orthognathic), Facial Reconstructive Surgery (Reconstruction), Facial Trauma Surgery (Trauma), Pediatric Trauma (Trauma)

ICON Instrument Trays

Each module within the system is highly customizable to match the surgeon’s needs.

  • 1.2 mm module (optional)
  • 1.6 mm module
  • 2.0 mm module
  • 2.0/2.4 mm locking module
  • Reconstruction module is optional
Tray